一、说明 Explanation
产品型号Model:JDCF-110
一次额定电压
Primary rated voltage: 110/√3 KV
额定频率: 50 Hz(允许偏差±0.5Hz)
RATED FREQUENCY: 50 HZ (tolerance
0.5 Hz)
二次绕组
Secondary winding
100/√3 V
额定电压
Rated Voltage:
0.5 级
准确级次
Accuracy level
140
VA
额定容量
Rated capacity
剩余电压绕组
Residual voltage winding
100 V
额定电压
Rated Voltage
3P 级
准确级次
Accuracy level
140
VA
额定容量
Rated capacity
标称电容
Nominal capacitance
载波耦合电容器 0.02 μF
Carrier coupled capacitor
C1 0.028421 μF
C2 0.06526 μF
二、试验内容Test content
1、 外观检验 Visual
inspection
互感器的金属件外露表面具有 良好 的防腐蚀层。
The exposed surface of the metal parts of the transformer
has a good anti-corrosion layer.
2、 电容分压器试验Capacitive voltage divider
电容分压器的密封性能 良好 。
Good sealing performance of the Capacitive voltage divider.
单节载波耦合电容器工频耐压试验一分钟通过 230 KV。
Power frequency withstand voltage test of single-section
carrier coupling capacitor passes 230kv in one minute.
低电压端子和接地端子之间工频耐压试验一分钟通过 4 KV。
The power frequency withstand voltage test between the low
voltage terminal and the grounding terminal passes 4kv in one minute.
电容单元编号
Capacitor unit number
电容器容量
Capacitor capacity
损耗角正切值tgδ
Tangent value of loss angle
局部放电
Partial discharge
20051713
C1 0.01855 μF
0.09 ℅
5pC
总电容量 C= 0.01985 μF
Total capacitance
3、 电磁单元试验Electromagnetic unit test
电磁单元编号Electromagnetic unit number:20052114
极性检验: 减 极 性Polarity test: Depolarity
密封性能: 良 好Sealing
performance: Good
一次绕组感应耐压试验: 频率 150 Hz, 时间40 s, 电压68KV, 通过。
First winding induction withstand
voltage test: Frequency 150Hz, time 40s, voltage 68kv, Pass.
中间变压器一次绕组低压端对地工频耐压一分钟通过10 KV(r.m.s), 通过。
Intermediate Transformer Primary
Winding low-voltage end-to-ground frequency withstand voltage one minute
through 10 KV (r.m.s) , Pass.
07
17
2025
JDCF-60W2-JDCF-72.5户外66KV电压互感器 60KV电压互感器 祝捷电气
来源:[上海祝捷电气科技有限公司]
联系人:曹先生
手机:13641820481
电话:021-31019117
传真:021-31019117
QQ:824359551
Email:824359551@qq.com
地址:上海上海市松江区松江区九亭大街110弄38号
品牌:祝捷电气
价格:1.00
元/台
供应地:上海上海市
产品型号:JDCF-66W2/0.05H