fundamental frequency range is 10 Hz to 110 kHz with 2 digit
resolution
Frequency range is 10 Hz to 100 kHz with 2 digit resolution. Output level is
variable from 4 V rms to 1 mV rms.
Oscillator distortion ( >600 ohm load, <3 Vrms)
10 Hz to 20 kHz < -93 dB (0.0022%) THD
Voltmeter
Hewlett-Packard's Model 339A Distortion Measurement Set is an ultra low
distortion measuring system complete with total harmonic distortion (THD)
analyzer, true-rms voltmeter, and sinewave oscillator. This small, lightweight
bench measurement set allows you to make THD distortion measurements as low as
0.0018% over a 10 Hz to 110 kHz frequency band including harmonics to 330
kHz.
For fast and easy THD measurements the built-in tracking oscillator in HP's
339A saves test time because you tune one instrument instead of two. Frequency
and level measurements are easy to do with HP's 339A's voltmeter, which offers
you a 1 mV to 300 V measurement range. The Relative Level mode has been
included to further simplify frequency response measurements. Just set a 0 dBm
reference at any frequency from 10 Hz to 110 kHz. Gain measurements can be read
directly from the easy-to-read meter.
Operation Simplicity
Automatic frequency tuning and set-level features allow you to make rapid,
error free THD measurements. The 339A's built-in tracking oscillator eliminates
the need to find the fundamental frequency and tune the analyzer for a null.
Just select your oscillator frequency and the rest is automatic. Automatic
set-level saves time by automatically setting 0 dB (100%) reference in the
distortion measuring mode. Front panel directional indicators light when the
input range setting is improper insuring accurate and repeatable measurements
where distortion as a function of a level (SINAD, for example) is desired.
Without this feature, measurements are very time consuming and tedious.
When an external stimulus is used, analyzer tuning is simplified by
directional indicator lights for reaching the fundamental null quickly and
easily.
现货 厂
家:美国惠普
Automatic
True RMS detection
Distortion Measurement
Set
Ultralow distortion measuring system complete with total harmonic
distortion (THD) analyzer, true rms voltmeter, and sinewave oscillator. THD
measurements over the 10 Hz to 110 kHz frequency band, including harmonics to
330 kHz. Also features built-in tracking oscillator.
Distortion
Measurements
measurement range is 100% to 0.01%, (0 dB to -80
dB)
Oscillator
20 kHz to 30 kHz < -85 dB
(0.0056%) THD
30 kHz to 50 kHz < -80 dB (0.01%) THD
50 kHz to 80 kHz
< -70 dB (0.032%) THD
80 kHz to 110 kHz < -65 dB (0.056%) THD
Range is 1 mV rms full scale to 300 V rms full scale.
05
12
2017
HP339A失真仪
来源:[广州普真仪科技有限公司]
联系人:曾先生
手机:13826285416
电话:020-34303393
传真:020-34303393
QQ:80176707
Email:puzheny@126.com
地址:广东省广州市广州市海珠区江丽路江丽东九号403
品牌:HP
价格:面议
元/台
供应地:广东省广州市
产品型号:HP339A