产品 产品信息
05 12 2017

ANDO AQ6330/AQ6331 便携光谱仪

当前位置: 首页> 仪器仪表> 电子测量仪器> 其他电子测量仪器
来源:[广州普真仪科技有限公司]
联系人:曾先生
手机:13826285416
电话:020-34303393
传真:020-34303393
QQ:80176707
Email:puzheny@126.com
地址:广东省广州市广州市海珠区江丽路江丽东九号403
品牌:ANDO
价格:面议 元/
供应地:广东省广州市
产品型号:AQ6330/AQ6331

产品名称:ANDO AQ6330/AQ 6331 便携光谱仪

AQ6331 Data_Sheet.pdf

现货85成新,完好现货。

应用场合:

光纤放大器,LED, FP-LD and DFB-LD激光器,无源光器件的测试评估

The AQ6330 is a portable optical spectrum analyzer (OSA) with the high performance required for 50 GHz and 100 GHz DWDM network testing. In both the C and L bands and beyond, wavelength rans is 1200 nm to 1700 nm. The AQ6331 is compact, yet has all the features required for DWDM system evaluation. Further, it has excellent wavelength resolution, with accuracy and dynamic range equal to that of any conventional bench-top OSA used in research and development applications

The AQ6330 OSA is suitable both for the installation and maintenance of DWDM systems, FTTx or CWDM networks, and for research and development applications.

  • Compact and lightweight - Approx. 315 (W) x 200 (H) x 225 (D) mm and only 10 kg., yet comes with a light source for wavelength calibration and a printer as standard features.
  • High wavelength accuracy - Features ±0.02 nm wavelength accuracy at 1520 to 1580 nm and ±0.05 nm accuracy at 1580 to 1620 nm, using an internal light source to perform wavelength calibration.
  • Internal wavelength calibration function - The built-in reference light source eliminates the need for an optical fiber connection to an external light source to perform wavelength calibration. Connection to  the reference light source is done automatically by an internal optical switch.
  • High dynamic range and high wavelength resolution - With dynamic range of 55 dB or more (peak plusmn;0.4 nm) and wavelength resolution of 0.05 nm (min.), 50 GHz channel-spaced DWDM systems can be measured.
  • High power measurement - Optical amplifier output and high output laser diodes in DWDM systems can be measured directly because the measurement level can range up to +20 dBm.
  • Low polarization dependency - Optical amplifier gain can be measured accurately because polarization dependency is as low as ±0.05 dB.
  • Long-term analysis function - Changes to each DWDM channel peak can be measured over time.
  • Convenient programming function - Shortens measurement time because measurement conditions and processes, etc., can be input to memory prior to measurement./li>
  • Individual traces of three wave-forms - Individual traces of three waveforms can be displayed. Can also compare two waveforms - a reference waveform and a measurement result - to determine the difference between the each.
  • Internal high-speed printer

 

  • Large 8.4 inch display

电话咨询获取底价