                conventional  smoke  detector  

  YT102  conventional  smoke  detector  
conventional  smoke  detector  with  CE  certificate  
Operating  Voltage  Range:                  9  to  28VDC  Volts  Non-polarized
Standby  Current:                                  ≤60µA  @  24  VDC  
Maximum  Alarm  Current  (LED  on:  )  ≤30mA  @  24  VDC
Operating  Humidity  Range:                  10%  to  93%  Relative  Humidity,  Non-condensing
Operating  Temperature  Range:          14°F  to  122°F  (-10°C  to50°C)
Adjustable  Sensitivity:                          1.06±.26%FT.
Height:                                                  2.2?  (55  mm)  installed  in  Base
Diameter:                                                  4.0?  (103  mm)
Weight:                                                  5.5  oz.  (155  g)

BEFORE  INSTALLING
NOTICE:  This  manual  should  be  left  with  the  owner/user  of  this  equipment.
IMPORTANT:  The  detector  must  be  tested  and  maintained  regularly  following  NFPA  72  requirements.  The  detector  should  be  cleaned  at  least  once  a  year.
GENERAL  DESCRJPTION
The  device  is  photoelectronic  detector  uses  a  state  of-the-art  optical  sensing  chamber.  This  detector  is  designed  to  provide  open  area  protection  and  to  be  used  with  most  conventional  fire  alarm  control  panel.  
Two  LEDs  on  each  detector  provide  local  360°  visible  alarm  indication.  They  flash  every  3~5  seconds  indicating  that  power  is  applied  and  the  detector  is  working  properly.  The  LEDs  latch  on  in  alarm.  LEDs  will  be  off  when  a  trouble  condition  exists  indicating  that  the  detector  sensitivity  is  outside  the  listed  limit.  The  alarm  can  be  reset  only  by  a  momentary  power  interruption.  
INSTALLATION
NOTE:  All  wiring  must  conform  to  applicable  local  codes,  ordinances,  and  regulations.
NOTE:  Verify  that  all  detector  bases  are  installed,  that  the  initiating-device  circuits  have  been  tested,  and  that  the  wiring  is  correct.

Remove  power  from  initiating-device  circuits  before  installing  detectors.

1.  Wire  the  sensor  base  per  the  wiring  diagram,  Figure  1.
2.  Install  the  sensor  into  the  sensor  base.  Push  the  sensor  into  the  base  while  turning  it  clockwise  to  secure  it  in  place.
3.  After  all  sensors  have  been  installed,  apply  power  to  the  control  unit.
4.  Test  the  sensor(s)  as  described  in  the  TESTING  section  of  this  manual.
5.  Notify  the  proper  authorities  that  the  system  is  in  operation.